Thermal Reclamation

Request A Quote

Omega Sinto 2025

FEATURES:

  • DEAD BED: Protects the ceramic insulation from abrasion, Provides additional thermal insulation, Enables the 3 year guarantee on furnace lining and bubble cap burners
  • THERMAL INSULATION: Ceramic blanket, ceramic board and ‘Dead Bed’ sand insulation, Reduces energy consumption
  • STAINLESS STEEL BUBBLE CAPS: Introduces gas/air mix into the furnace, Provides fluidization of sand, Stainless steel construction for long life
  • HEAT EXCHANGER AS STANDARD: Takes heat energy from the hot sand and warms the fluidization air, Reduces gas consumption, Zero maintenance

Advantages

ADVANTAGES OF PX THERMAL DESIGN

  • Reliable Performance
  • Robust construction
  • Minimal maintenance costs
  • Fast warm up times
  • Suitable for continuous or intermittent operation
  • Modular low thermal mass furnace lining
  • Fully-automatic PLC operation & Self Diagnostic controls
  • No burner tubes to maintain
  • Multi-zone stainless steel gas/air fluidization modules
  • Individual zone temperature controls
  • No castable or refractory brick
  • No afterburner requirement
  • No hot sand discharge gates required
  • No moving parts in the Calciner, Heat Exchanger or Cooler Classifier
  • Sand treatment time appropriate for each application
  • Integral Heat Exchanger to preheat the fluidizing combustion air
  • Excellent environmental conformity for VOC’s and particulates
  • Integral cooling and classification
  • No direct fluid bed metal containment tank
  • Stress-free fluid bed containment
  • Unique DEAD BED (patented)

Specifications

Thermal Reclamation

Thermal Reclaimer Combustion Chamber Moled Selector
Loss on Ignition % Up ToNatural Gas # Average ConsumptionPropane # Average Consumption
TPH1%1.5%2.0%2.5%3.0%3.5%4.0%
.25PXO.6GPXO.6GPXO.6GPX0.6GPX0.6GPX0.6GPX1G1506 ft3/T 47 m3/mT20 lb/T 10 Kg/mT
0.5PXO.6GPX1GPX1GPX1GPX1.5GPX1.5GPX1.5G1090 ft3/T 34 m3/mT16 lb/T 8 Kg/mT
1.0PX1.5GPX1.5GPX2GPX2GPX3GPX3GPX3G897 ft3/T 28 m3/mT12 lb/T 6 Kg/mT
1.5PX2GPX3GPX3GPX3GPX4GPX4GPX5G833 ft3/T 26 m3/mT12 lb/T 6 Kg/mT
2.0PX3GPX3GPX4GPX4GPX5GPX6GPX6G801 ft3/T 25 m3/mT12 lb/T 6 Kg/mT
2.5PX3GPX4GPX5GPX6GPX6GPX7GPX8G801 ft3/T 25 m3/mT12 lb/T 6 Kg/mT
3.0PX4GPX5GPX6GPX7GPX7GPX8GPX9G737 ft3/T 23 m3/mT10 lb/T 5 Kg/mT
4.0PX5GPX7GPX7GPX9GPX10GPX11GPX12G737 ft3/T 23 m3/mT10 lb/T 5 Kg/mT
5.0PX7GPX8GPX9GPX11GPX12GPX14GPX15G737 ft3/T 23 m3/mT10 lb/T 5 Kg/mT
6.0PX8GPX10GPX11GPX13GPX15GPX16G704 ft3/T 22 m3/mT10 lb/T 5 Kg/mT
8.0PX11GPX13G737 ft3/T 23 m3/mT10 lb/T 5 Kg/mT
10.0PX14GPX16G704 ft3/T 22 m3/mT10 lb/T 5 Kg/mT
12.0PX17G737 ft3/T 23 m3/mT10 lb/T 5 Kg/mT

SIZING

  • All systems are designed using computer-aided calculations to ensure all systems meet the requirements of the individual customer.
  • Typical utilities are around 19.25 m³ (680ft³) / hr natural gas and 40kW installed electrical power, per metric ton of material processed. Compressed air and water services will also be required.
  • The unit is designed to accommodate Loss-On-Ignition (LOI) levels of feed material.
  • Thermal units are sized based on Loss-On-Ignition (LOI) levels relative to combustion of residual resin and appropriate oxygen requirements.

Request More Info

Specs